HY Serie - Hanyoung - Controles de Temperatura Digital
- Fabricante: Hanyoung Nux
- Código de Producto: HY Serie Digital
- Existencia: Disponible
Control de Temperatura HY Serie Digital
Características principales:
- Control proporcional o ON/OFF
- Simple selección de temperatura
- Configuración de alarma (HY-8200s)
- Indicador digital
Suffix code
Model | Code | Information | ||||||
HY - | Digital temperature controller | |||||||
Dimension | 8000S | 96 × 96 mm | ||||||
8200S | 96 × 96 (alarm setting general specification) | |||||||
72D | 72 × 72 | |||||||
48D | 48 × 48 | |||||||
Control type | F | ON/OFF control | ||||||
P | Proportional control | |||||||
Input | K | K thermocouple | ||||||
J | J thermocouple | |||||||
R | R thermocouple | |||||||
D | RTD KPt 100 Ω | |||||||
P | RTD Pt 100 Ω (IEC) | |||||||
V | 1 - 5 V d.c | |||||||
C | 4 - 20 mA d.c | |||||||
Control Output | M | Relay | ||||||
C | Current output (4 - 20 mA d.c) | |||||||
S | S.S.R (voltage pulse output, 12 V d.c) | |||||||
Alarm Output | N | None | ||||||
O | High alarm (HY-8200S) | |||||||
Control action(Internal selection) | R | Reverse action (heating control) | ||||||
D | Direct action (cooling control) | |||||||
Range Code | Refer to the range and input code |
Classification | code | HY-8000S, 8200S | HY-72D | HY-48D | |||
Input type | Range (°C) | Input type | Range (°C) | Input type | Range (°C) | ||
Thermocouple | 4 | - | - | - | - | K, J | 0 ~ 299 |
5 | - | - | - | - | 0 ~ 399 | ||
6 | K, J | 0 ~ 199 | K, J | 0 ~ 199 | - | - | |
7 | 0 ~ 299 | 0 ~ 299 | |||||
8 | 0 ~ 399 | 0 ~ 399 | |||||
9 | - | 0 ~ 599 | |||||
10 | 0 ~ 599 | K | 0 ~ 799 | ||||
11 | K | 0 ~ 799 | - | ||||
12 | - | 0 ~ 1199 | |||||
13 | 0 ~ 1199 | R | 600 ~ 1699 | ||||
14 | R | 600 ~ 1699 | - | - | |||
RTD | 1 | - | - | - | - | - | -49 ~ 49 |
2 | Pt100 O | -99 ~ 99 | Pt100 O | -99 ~ 99 | -99 ~ 99 | ||
3 | -99 ~ 199 | -99 ~ 199 | 0 ~ 199 | ||||
4 | 0 ~ 99 | 0 ~ 99 | 0 ~ 299 | ||||
5 | - | - | 0 ~ 399 | ||||
6 | 0 ~ 199 | 0 ~ 199 | - | - | |||
7 | 0 ~ 299 | 0 ~ 299 | |||||
8 | 0 ~ 399 | 0 ~ 399 | |||||
Voltage/Current (DC) | - | 1 - 5 V | 0 ~ 99 | 1 - 5 V | 0 ~ 99 | 1 - 5 V | 0 ~ 99 |
- | 4 - 20 mA | 0 ~ 99 | 4 - 20 mA | 0 ~ 99 | 4 - 20 mA | 0 ~ 99 |
Specification
Model | HY-8000S | HY-8200S | HY-72D | HY-48D | |
Appearance | |||||
W × H × D (mm) | 96 × 96 × 125 | 96 × 96 × 125 | 72 × 72 × 110 | 48 × 48 × 100 | |
Power Voltage | 110 / 220 V a.c (50 / 60 Hz) | ||||
Power Consumption | 3 VA | ||||
Input | Input(Sensor type) selection by the configuration suffix code. a) Thermo couple : K, J, R b) R.T.D : KPt100 Ω(KS), Pt100 Ω(IEC 751) c)DC current : 4 to 20 mA d) DC voltage : 1 to 5 V DCnt | ||||
Control Output | Relay contact : 250 V AC 3 A (Resistive load), SSR: 12 V DC (Constant voltage pulse) [Load resistance min. 800 Ω], Current: 4 - 20 mA DC [Load resistance max. 600 Ω) | ||||
Control Method | Proportional or ON/OFF control | ||||
Alarm Output | - | Relay contact : 250 V a.c 3 A | - | ||
Setting Method | By B.C.D S/W | ||||
Permissible input resistance | Thermocouple : Max. 250 Ω, R.T.D : Max. 10 Ω | ||||
Indication range | Setting temperature range | ||||
Display | L.E.D Display | ||||
Setting and display accuracy | Set Value : ±1.0 % of F.S, Display : ±0.5 % of F.S | ||||
Control sensitivity | Approx 0.2 % F.S (Fixed) | ||||
Proportional Cycle | Relay contact : 25 ~ 30 sec SSR : 2 ~ 4 sec | ||||
Reset Range | Max. ± 1.5 % of Range | ||||
Dielectric Strength | 2,000 V AC 50/60 Hz for 1 minute (Primary terminal-secondary terminal) | ||||
Vibration | Resistance | 2 - 55 Hz, X · Y · Z each position for 10 minutes | |||
Durability | 10 - 55 Hz, X · Y · Z each position for 2 hours | ||||
Shock | Resistance | 100 ㎨ 6 positions, each 3 times | |||
Durability | 300 ㎨ 6 positions, each 3 times | ||||
Life | Mechanical | Min. 10 million times (Relay type) | |||
Electrical | Min. 0.3 million times (Relay type) | ||||
Ambient temperature and humidity | 0 ~ 50 °C(32 ~ 122°F) · 35 ~ 85 % R.H. (Without freeze) |
Etiquetas: HY Serie